Pentacam report in your template

Upload the Pentacam file. soft.report reads the exam maps and indices and drafts the report in your template, for you to review and sign.

What soft.report reads in this exam

Curvature and anterior and posterior elevation maps, pachymetry and BAD-D index.

Sample report

Illustrative example with fictitious data. OCULUS Pentacam HR, 4 Maps Refractive and Belin/Ambrósio Enhanced Ectasia Display. Male patient, 24 years old.

CORNEAL TOMOGRAPHY (SCHEIMPFLUG) — PENTACAM HR

Capture quality (QS): OK in both eyes.

Right eye

K1 43.2 D @ 4°, K2 44.4 D @ 94°, Km 43.8 D. Corneal astigmatism of 1.2 D with-the-rule.

Kmax 44.9 D.

Pachymetry at the apex 541 µm and at the thinnest point 528 µm.

Elevation at the thinnest point: anterior +3 µm, posterior +5 µm.

BAD-D 1.21. Axial map with a symmetric bowtie.

Left eye

K1 44.1 D @ 12°, K2 46.0 D @ 102°, Km 45.0 D. Corneal astigmatism of 1.9 D.

Kmax 48.6 D, inferotemporal.

Pachymetry at the apex 489 µm. Thinnest point 472 µm, displaced inferotemporally 0.9 mm from the apex.

Elevation at the thinnest point: anterior +9 µm, posterior +21 µm, abnormal.

BAD-D 3.10, abnormal (Df 2.4; Db 3.6; Dp 2.9; Dt 2.8; Da 1.6). Pachymetric progression index above normal.

Axial map with inferior steepening and an asymmetric bowtie.

Conclusion

OD: corneal tomography without signs of ectasia.

OS: tomographic pattern consistent with early corneal ectasia (keratoconus). The findings are increased posterior elevation, inferotemporally displaced thinning, abnormal BAD-D and inferior steepening.

There is marked asymmetry between the eyes.

What you upload

The PDF, image or DICOM file the device produces. For DICOM, patient identifiers in the metadata are removed in your browser before upload.

In your template

You upload one of your own reports as the template. soft.report reproduces the header, tables and spacing, and the AI fills in only the exam fields. The reports you review guide the style and vocabulary of the next ones.

What stays with the physician

soft.report is a diagnostic aid: it delivers a draft. The clinical decision, the review and the signature belong to the physician.

Frequently asked questions

Does the Pentacam report use the BAD-D?

Yes. The BAD-D index goes into the draft together with curvature, anterior and posterior elevation and pachymetry.

Is the Pentacam report ready to sign?

No. You get a draft in your template. The review, the conclusion and the signature always belong to the physician.

Can I use my own report template?

Yes. You upload one of your reports as the template and soft.report reproduces the header, tables and spacing.

Other exams

Discover soft.report